Response to Reviewer mc8g
Thank you for your review, we are happy that you found our paper well-written, strong, and benefitial to the community. Please, find our response to your concerns below.
- **Confidence intervals:** Initially, we did not include the confidence intervals for two reasons: 1) They are all quite small; the majority of standard errors are < 0.1%. This should have been explicitly stated in the paper. 2) As you accurately pointed out, the space limitations; since the confidence intervals are not very informative, adding a “±0.002” to every column would make the tables even longer and unreadable. Given the small standard errors on the means, most of the differences between methods are statistically significant. We do, however, have the confidence intervals for our experiments, and are happy to include them in the supplementary material. For example, see the confidence intervals (SEM) reported below (RN18/ViT, MDL):
| Dataset | ResNet-18 | ViT-S |
| --- | :---: | :---: |
| Aircrafts | 90.1±0.013 | 89.1±0.002 |
| Birds | 83.8±0.058 | 92.5±0.034 |
| DTD | 82.3±0.002 | 86.3±0.002 |
| Fungi | 68.4±0.116 | 75.1±0.086 |
| ImageNet | 61.4±0.145 | 74.6±0.088 |
| Omniglot | 94.3±0.037 | 92.0±0.047 |
| QuickDraw | 82.6±0.020 | 80.6±0.041 |
| VGG Flowers | 92.2±0.086 | 93.5±0.090 |
| CIFAR10 | 83.0±0.001 | 75.9±0.002 |
| CIFAR100 | 75.1±0.002 | 70.8±0.001 |
| MNIST | 95.4±0.001 | 91.3±0.001 |
| MSCOCO | 58.8±0.130 | 62.8±0.063 |
| Traffic Signs | 82.9±0.107 | 87.2±0.032 |
- **Comparison N=2,4, ResNet/ViT:** In practice, N is a hyperparameter that is chosen heuristically, and the results do not change much when N=2,3,4,5, etc. The big difference comes from N=1, N=small, N=large. This is true for both ResNet and ViT architectures. Please, find an analysis of small Ns below (RN18, MDL, N=2,3,4):
| | N=2 | N=3 | N=4 |
| --- | :---: | :---: | :---: |
| Mean acc. (MetaDataset, NumEps=600) | 80.3 | 80.7 | 80.7 |
Since the differences between small values of N are insignificant, in our experiments we arbitrarily chose N=3 as a value that is greater than 1 but small enough not to impose a substantial computational burden. We did not attempt to carefully tune this hyperparameter.
- **Additional baselines:** Thank you for providing these additional references, we have added them to Table 3.