In this article, commonly used overhead line insulators are experimentally studied to propose an intelligent diagnosis system (IDS) to correctly identify the insulator health condition in real time. The proposed IDS is developed based on the three diagnostic indicators, third to fifth harmonic ratio of the insulator’s leakage current (LC), cosine of the phase angle of the LC fundamental component, and the ratio of the maximum electric field stress (EFS) to flashover electric field (EF) of the insulator. The proposed diagnostic approach can identify the normal, abnormal, and critical conditions of an insulator based on the above-mentioned indicators. Leakage current and flashover voltage are experimentally measured for the studied insulators under various health conditions. Then, recorded data are analyzed to calculate the proposed indicators corresponding to each insulator state. Measured and calculated data are used to intelligently quantify threshold limits of each indicator based on the visualization algorithm. In this algorithm, different classifiers are trained with experimental data. The decision tree, which provided the highest precision, is employed to determine reference boundaries of the three indicators for each health state of the insulator. Embedded sensors can measure and sample the LC and EFS of the insulator. Sampled data are transmitted to a central processing unit (CPU)-based receiver via a radio communication channel to automate the identification of the insulator state in real time.
Paper
Full text
Online Condition Monitoring of Overhead Insulators Using Pattern Recognition Algorithm
Semantic Scholar · Engineering · 2022
Abstract
In this article, commonly used overhead line insulators are experimentally studied to propose an intelligent diagnosis system (IDS) to correctly identify the insulator health condition in real time. The proposed IDS is developed based on the three diagnostic indicators, third to fifth harmonic ratio of the insulator’s leakage current (LC), cosine of the phase angle of the LC fundamental component, and the ratio of the maximum electric field stress (EFS) to flashover electric field (EF) of the insulator. The proposed diagnostic approach can identify the normal, abnormal, and critical conditions of an insulator based on the above-mentioned indicators. Leakage current and flashover voltage are experimentally measured for the studied insulators under various health conditions. Then, recorded data are analyzed to calculate the proposed indicators corresponding to each insulator state. Measured and calculated data are used to intelligently quantify threshold limits of each indicator based on the visualization algorithm. In this algorithm, different classifiers are trained with experimental data. The decision tree, which provided the highest precision, is employed to determine reference boundaries of the three indicators for each health state of the insulator. Embedded sensors can measure and sample the LC and EFS of the insulator. Sampled data are transmitted to a central processing unit (CPU)-based receiver via a radio communication channel to automate the identification of the insulator state in real time.